501-17 Roof Opening Panel
|
2014 Fiesta
|
General Procedures
|
Procedure revision date:
05/8/2013
|
Power Roof Opening Panel Initialization
NOTE:
A new roof opening panel motor only moves towards the vent position until it is initialized.
NOTE:
An initialization procedure that was interrupted or not completed can be started again after cycling the ignition from ON
to OFF and back to ON again.
-
Place the ignition switch in the RUN position. For initializing an existing roof opening panel motor, skip to Step 6.
-
For a new roof opening panel motor
, press and hold the front portion of the control switch until the roof opening panel glass moves slightly past the full vent
position (approximately 2 mm (0.0787 in)) and stops.
-
NOTE:
(Movement starts approximately 3 seconds after the switch is pressed)
Quickly (within 0.5 second) release, then press and hold the front portion of the control switch while the roof opening panel
glass move to the full open position and then back to the full closed position.
-
Release the switch and verify successful initialization by performing one-touch open and one-touch vent operations.
-
For an existing roof opening panel motor
, press and hold the front portion of control switch until the roof opening panel glass moves to the full vent position, then
release the switch.
-
Press and hold the front portion of the control switch for approximately 10 seconds until the roof opening panel glass moves
slightly past the full vent position (approximately 2 mm (0.0787 in)) and stops.
-
Quickly (within 0.5 second) release, then press and hold the front portion of the control switch while the roof opening panel
glass moves to the full open position and then back to the full closed position.
-
Release the switch and verify successful initialization by performing one-touch open and one-touch vent operations.
Copyright © Ford Motor Company